SPECIFICATIONS
Performance
typical for an aluminum target.
- Mesuring
range (sensors):
- 15N:
Up to ±0.035 inch (±0.889 mm).
- 20N:
Up to ±0.075 inch (±1.905 mm).
Nonlinearity:
- ±0.1%
to ±0.5% FSO; application dependent.
Output:
KD-5100:
Long-term
stability (nominal; stabilized at 70°F [21°C]
scale factor dependent):
- 5 x 10-6
inches/month (1.27 x 10-4 mm/month).
Thermal
sensitivity at null:
- Application
dependent; <5 mV per °F.
Frequency
response:
RMS input
displacement resolution (if bandwidth limited to 5 kHz):
- 4 x 10-9
per root bandwidth in Hz = inches (1 x 10-7
per root bandwidth in Hz = mm);
noise slightly higher in KDM-8200.
Input voltage:
Power consumption
(system):
Power dissipation
(sensors):
- <50 µW
per 15N sensor; <1.5 mW per 20N sensor.
Output characteristics:
- Operating
temperature range:
- Electronics:
-4°F to +140°F (-20°C to +60°C).
- Sensors:
-62°F to +220°F (-52°C to +105°C).
- Cryogenic
20N sensor: +4°K to +220°F (+105°C).
Storage
temperature range:
- Electronics:
-26°F to +180°F (-32°C to +82°C).
- Sensors:
-62°F to +220°F (-52°C to +105°C).
- Cryogenic
20N sensor: +4°K to +220°F (+105°C).
Weight (with
5-foot cable):
- Electronics:
2.5 ounces (70 grams).
- 15N-001
sensor: 0.61 ounces (17.3 grams).
- 20N sensor:
0.59 ounces (16.8 grams).
|
|