| | 2U ![[Sensor 2U]](images/sensr-2U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel. | Standard KµDA Sensor Type 2U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.002 (0.05) | 0.002 (0.05) | | Full scale output voltage for testing | Volts dc | 10 | ±10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.03 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.020 (0.5) | 0.010 (0.25) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.3 0.4 | 0.3 0.5 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.04 0.08 | 0.06 0.12 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.030 (0.75) | 0.015 (0.375) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.8 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.3 0.4 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.04 0.15 | 0.06 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 4U ![[Sensor 4U]](images/sensr-4U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel. | Standard KµDA Sensor Type 4U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.005 (0.125) | 0.005 (0.125) | | Full scale output voltage for testing | Volts dc | 10 | ±10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.050 (1.25) | 0.020 (0.50) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.3 0.5 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.04 0.08 | 0.06 0.12 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.070 (1.75) | 0.025 (0.625) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.04 0.15 | 0.06 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 9U ![[Sensor 9U]](images/sensr-9U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel. | Standard KµDA Sensor Type 9U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.010 (0.25) | 0.015 (0.375) | | Full scale output voltage for testing | Volts dc | 10 | 10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.100 (2.5) | 0.100 (2.5) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.08 | 0.03 0.09 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.150 (3.75) | 0.150 (3.75) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.15 | 0.04 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 12U ![[Sensor 12U]](images/sensr-12U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel. | Standard KµDA Sensor Type 12U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.016 (0.4) | 0.016 (0.4) | | Full scale output voltage for testing | Volts dc | 10 | 10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.160 (4.0) | 0.160 (4.0) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.08 | 0.03 0.09 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.240 (6.0) | 0.240 (6.0) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.15 | 0.04 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 16U ![[Sensor 16U]](images/sensr-16U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. | Standard KµDA Sensor Type 16U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.020 (0.5) | 0.020 (0.5) | | Full scale output voltage for testing | Volts dc | 10 | 10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.200 (5.0) | 0.200 (5.0) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.08 | 0.03 0.09 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.320 (8.0) | 0.320 (8.0) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.15 | 0.04 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 26U ![[Sensor 26U]](images/sensr-26U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. | Standard KµDA Sensor Type 26U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.032 (0.8) | 0.032 (0.8) | | Full scale output voltage for testing | Volts dc | 10 | 10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.320 (8.0) | 0.320 (8.0) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.3 0.5 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.08 | 0.03 0.09 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.500 (12.5) | 0.500 (12.5) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.15 | 0.04 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 38U  Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. | Standard KµDA Sensor Type 38U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.050 (1.2) | 0.050 (1.2) | | Full scale output voltage for testing | Volts dc | 10 | 10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.500 (12) | 0.500 (12) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.4 0.4 | 0.3 0.5 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.08 | 0.03 0.09 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 0.800 (20.25) | 0.800 (20.25) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.15 | 0.04 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | 51U ![[Sensor 51U]](images/sensr-51U.GIF) Dimensions shown in inches (mm). back to top | Non-magnetic targets characterized on aluminum. Magnetic targets characterized on 4130 steel. | Standard KµDA Sensor Type 51U | Non-magnetic targets | Magnetic targets | | Offset | inch (mm) | 0.100 (1.5) | 0.100 (1.5) | | Full scale output voltage for testing | Volts dc | 10 | 10 | | Sensor thermal sensitivity shift with active temp. compensation | %/°C maximum | ±0.01 (standard range, 10°C - 50°C) | ±0.01 (standard range, 25°C - 100°C) | | Standard measuring range | inch (mm) | 0.600 (15) | 0.600 (15) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.4 0.4 | 0.3 0.5 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.1 0.2 | 0.1 0.2 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.08 | 0.03 0.09 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | Extended measuring range | inch (mm) | 1.000 (25.5) | 1.000 (25.5) | | Nonlinearity with 3 point calibration (+/-%FS) | typical maximum | 0.7 1.0 | 0.8 1.0 | | Nonlinearity with 21 point calibration (+/-%FS) | typical maximum | 0.2 0.3 | 0.2 0.3 | | Resolution (P-P %FS) 100 Hz mid scale 100 Hz full scale | typical typical | 0.03 0.15 | 0.04 0.15 | | Resolution (P-P %FS) 1000 Hz mid scale 1000 Hz full scale | typical typical | 0.10 0.30 | 0.10 0.30 | | |