[KµDA][Features][Overview][Sensors][Applications][Specifications]

[2U][4U][9U][12U][16U][26U][38U][51U]

 



2U

[Sensor 2U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel.

Standard KµDA Sensor Type 2U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.002
(0.05)
0.002
(0.05)
Full scale output voltage for testing Volts dc 10 ±10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.03 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.020
(0.5)
0.010
(0.25)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.3
0.4
0.3
0.5

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.04
0.08
0.06
0.12

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.030
(0.75)
0.015
(0.375)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.8
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.3
0.4
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.04
0.15
0.06
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


4U

[Sensor 4U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel.

Standard KµDA Sensor Type 4U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.005
(0.125)
0.005
(0.125)
Full scale output voltage for testing Volts dc 10 ±10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.050
(1.25)
0.020
(0.50)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.3
0.5

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.04
0.08
0.06
0.12

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.070
(1.75)
0.025
(0.625)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.04
0.15
0.06
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


9U

[Sensor 9U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel.

Standard KµDA Sensor Type 9U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.010
(0.25)
0.015
(0.375)
Full scale output voltage for testing Volts dc 10 10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.100
(2.5)
0.100
(2.5)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.08
0.03
0.09

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.150
(3.75)
0.150
(3.75)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.15
0.04
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


12U

[Sensor 12U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel. Sensor not available with extension cable for steel.

Standard KµDA Sensor Type 12U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.016
(0.4)
0.016
(0.4)
Full scale output voltage for testing Volts dc 10 10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.160
(4.0)
0.160
(4.0)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.08
0.03
0.09

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.240
(6.0)
0.240
(6.0)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.15
0.04
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


16U

[Sensor 16U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel.

Standard KµDA Sensor Type 16U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.020
(0.5)
0.020
(0.5)
Full scale output voltage for testing Volts dc 10 10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.200
(5.0)
0.200
(5.0)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.08
0.03
0.09

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.320
(8.0)
0.320
(8.0)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.15
0.04
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


26U

[Sensor 26U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel.

Standard KµDA Sensor Type 26U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.032
(0.8)
0.032
(0.8)
Full scale output voltage for testing Volts dc 10 10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.320
(8.0)
0.320
(8.0)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.3
0.5

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.08
0.03
0.09

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.500
(12.5)
0.500
(12.5)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.15
0.04
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


38U

[Sensor 38U

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel.

Standard KµDA Sensor Type 38U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.050
(1.2)
0.050
(1.2)
Full scale output voltage for testing Volts dc 10 10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.500
(12)
0.500
(12)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.4
0.4
0.3
0.5

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.08
0.03
0.09

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
0.800
(20.25)
0.800
(20.25)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.15
0.04
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30

 


 


51U

[Sensor 51U]

Dimensions
shown in
inches (mm).

back to top

Non-magnetic targets characterized on aluminum.
Magnetic targets characterized on 4130 steel.

Standard KµDA Sensor Type 51U

Non-magnetic
targets

Magnetic
targets

Offset inch
(mm)
0.100
(1.5)
0.100
(1.5)
Full scale output voltage for testing Volts dc 10 10
Sensor thermal sensitivity shift with active temp. compensation %/°C
maximum
±0.01 (standard
range, 10°C - 50°C)
±0.01 (standard
range, 25°C - 100°C)
Standard measuring range inch
(mm)
0.600
(15)
0.600
(15)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.4
0.4
0.3
0.5

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.1
0.2
0.1
0.2

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.08
0.03
0.09

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30
Extended measuring range inch
(mm)
1.000
(25.5)
1.000
(25.5)

   Nonlinearity with 3 point
   calibration (+/-%FS)

typical
maximum
0.7
1.0
0.8
1.0

   Nonlinearity with 21 point
   calibration (+/-%FS)

typical
maximum
0.2
0.3
0.2
0.3

   Resolution (P-P %FS)
      100 Hz mid scale
      100 Hz full scale

typical
typical
0.03
0.15
0.04
0.15

   Resolution (P-P %FS)
      1000 Hz mid scale
      1000 Hz full scale

typical
typical
0.10
0.30
0.10
0.30