| | .5U1 / .5U2 ![[Sensor .5U1 / .5U2]](images/sensr-dot5U15U2.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | .5U1 | .5U2 | | Target material | non-ferrous ferrous | Yes No | No Yes | | Measuring range | mil mm | 20 0.5 | | Offset | mil mm | 2 0.05 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.004 0.0001 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.1 0.003 | | Factory sensitivity** | mV/mil | 100 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 1U1 ![[Sensor 1U1]](images/sensr-1U1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 1U1 | | Target material | non-ferrous ferrous | Yes No | | Measuring range | mil mm | 40 1 | | Offset | mil mm | 0.006 0.13 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.004 0.0001 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.2 0.005 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 1UEP ![[Sensor 1UEP]](images/sensr-1UEP.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 1UEP | | Target material | non-ferrous ferrous | * Yes | | Measuring range | mil mm | 40 1 | | Offset | mil mm | 0.006 0.13 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.004 0.0001 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.2 0.005 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -452° to +400° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 2UB1 ![[Sensor 2UB1]](images/sensr-2UB1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 2UB1 | | Target material | non-ferrous ferrous | Yes * | | Measuring range | mil mm | 80 2 | | Offset | mil mm | 0.015 0.38 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.008 0.0002 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.4 0.01 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 2S1 ![[Sensor 2S1]](images/sensr-2S1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 2S1 | | Target material | non-ferrous ferrous | Yes * | | Measuring range | mil mm | 80 2 | | Offset | mil mm | 0.015 0.38 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.008 0.0002 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.4 0.01 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 2UEP ![[Sensor 2UEP]](images/sensr-2UEP.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 2UEP | | Target material | non-ferrous ferrous | * Yes | | Measuring range | mil mm | 80 2 | | Offset | mil mm | 0.025 0.63 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.008 0.0002 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.4 0.01 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -452° to +400° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 3U1 ![[Sensor 3U1]](images/sensr-3U1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 3U1 | | Target material | non-ferrous ferrous | Yes * | | Measuring range | mil mm | 120 3 | | Offset | mil mm | 0.020 0.51 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.012 0.0003 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.6 0.015 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 4S1 ![[Sensor 4S1]](images/sensr-4S1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 4S1 | | Target material | non-ferrous ferrous | Yes Yes | | Measuring range | mil mm | 160 4 | | Offset | mil mm | 0.020 0.51 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.016 0.0004 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.8 0.02 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 4SB  Dimensions shown in inches (mm). back to top | | Sensor Type | 4SB | | Target material | non-ferrous ferrous | Yes * | | Measuring range | mil mm | 160 4 | | Offset | mil mm | 0.030 0.75 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.016 0.0004 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 0.8 0.02 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 6UEP ![[Sensor 6UEP]](images/sensr-6UEP.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 6UEP | | Target material | non-ferrous ferrous | Yes Yes | | Measuring range | mil mm | 240 6 | | Offset | mil mm | 0.035 0.89 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.024 0.0006 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 1.2 0.03 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -452° to +400° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 6U1 ![[Sensor 6U1]](images/sensr-6U1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 6U1 | | Target material | non-ferrous ferrous | Yes * | | Measuring range | mil mm | 240 6 | | Offset | mil mm | 0.035 0.89 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.024 0.0006 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 1.2 0.03 | | Factory sensitivity** | mV/mil | 10 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 15U2 ![[Sensor 15U2]](images/sensr-15U2.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 15U2 | | Target material | non-ferrous ferrous | Yes Yes | | Measuring range | mil mm | 600 15 | | Offset | mil mm | 0.150 3.81 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.060 0.0015 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 3.0 0.075 | | Factory sensitivity** | mV/mil | 1 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 15U1 ![[Sensor 15U1]](images/sensr-15U1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 15U1 | | Target material | non-ferrous ferrous | Yes * | | Measuring range | mil mm | 600 15 | | Offset | mil mm | 0.150 3.81 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.060 0.0015 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 3.0 0.075 | | Factory sensitivity** | mV/mil | 1 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | *Must specify actual target material. Performance specification may change. **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 30U2 ![[Sensor 30U2]](images/sensr-30U2.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 30U2 | | Target material | non-ferrous ferrous | Yes Yes | | Measuring range | mil mm | 1200 30 | | Offset | mil mm | 0.3 7.5 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.120 0.003 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 6.0 0.15 | | Factory sensitivity** | mV/mil | 1 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 30U1 ![[Sensor 30U1]](images/sensr-30U1.GIF) Dimensions shown in inches (mm). back to top | | Sensor Type | 30U1 | | Target material | non-ferrous ferrous | Yes Yes | | Measuring range | mil mm | 1200 30 | | Offset | mil mm | 0.3 7.5 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.120 0.003 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 6.0 0.15 | | Factory sensitivity** | mV/mil | 1 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. | 60U1 ![[Sensor 60U1]](images/sensr-60U1.GIF) Dimensions shown in inches (mm). | Sensor Type | 60U1 | | Target material | non-ferrous ferrous | Yes Yes | | Measuring range | mil mm | 2400 60 | | Offset | mil mm | 0.6 15 | Resolution (<=mid range) Static (unity bandwidth) | mil mm | 0.240 0.006 | Nonlinearity (±0.5% of measuring range) | ±mil ±mm | 12.0 0.30 | | Factory sensitivity** | mV/mil | 1 | Operating temperature Sensor and cable | °F | -67° to +220° | | Frequency response | Static to 50 kHz (-3dB pt.) | | Thermal sensitivity shift | 0.1% FSO/°F without temp.comp.; 0.02% FSO/°F with temp. comp. | **Sensitivities are user-adjustable from 1 mV/mil to 100 mV/mil, unipolar or bipolar output, application dependent. back to top | | |