800-552-6267

KD-2306
Single-channel multi-purpose non-contact
displacement sensing system

> Supports both dual and single coil sensors
> Terminal I/O connections
> Auto-synchronization of multiple channels
> Analog DC and 4-20mA outputs
> Single ended, bipolar, and differential voltage outputs
> Front face coarse and fine calibration controls
> RoHS compliant and CE marked

 

 

KD-2306 phots

  • KD-2306 DATA SHEET PDF
  • KD-2306 MANUAL PDF
  • 3D MODEL
  • SPECS
  • SENSORS
  • CERTIFICATIONS
  • OPTIONS
  • ACCESSORIES

KD-2306 Product ManualiconKD-2306 User Manual

 

 

 

 

 

 

 

 

 

 


Electronics
IGS format
STEP format
KD-2306

Sensor
IGS format
STEP format
.5SU sensor
.5SUM sensor
1S sensor
1SM sensor
1U1 sensor
1SU sensor
1SUM sensor
2S1 sensor
2UB1 sensor
2S sensor
3U1 sensor
4S1 sensor
4SB sensor
6U1 sensor
6C sensor
8C sensor
15U1 sensor
10C sensor
10CU sensor
30U1 sensor
12CU sensor
60U1 sensor
1UEP sensor
2SMT sensor
9U sensor
12U sensor
16U sensor
26U sensor
38U sensor
51U sensor

 

The following specifications can be applied to the full range of systems using standard sensor
options in the sensors chart. Each sensor has specific performance specifications that
can be better than those listed below.

Resolution 0.01%FS
Frequency response 50KHz (-3dB point) Higher response available on request.
Nonlinearity <1%FS
Thermal sensitivity Standard 0.1%FS/°F; compensated 0.02%FS/°F
Output options 0-10 VDC (standard); 0-5 VDC ±5 VDC, 4-20 mA
Operating temperature range Electronics +32°F to +132°F (0°C to +55°C)
Storage temperature range Electronics -67°F to +220°F (-55°C to +105°C)
Power supply requirements Voltage +15 to +30 Vdc
Voltage regulation ±1/2 Vdc
Current 150 mA

 

STANDARD TEMPERATURE SENSORS
– 67° TO +220° F (–55° TO +105° C)

SENSOR
click to view
STANDARD
MEASURING
RANGE
TARGET
MATERIAL
STATIC
RESOLUTION
 
inch
mm
non-fer
ferrous
μ in
μ m
.5SU / .5SUM
0.020
0.5
.5SU
.5SUM
4
0.1
1S /1SM
0.040
1.0
1S
1SM
4
0.1
1U1
0.040
1.0
4
0.1
1SU / 1SUM
0.050
1.3
1SU
1SUM
5
0.1
2S1
0.080
2.0
8
0.2
2UB1
0.080
2.0
8
0.2
2S
0.100
2.5
10
0.3
3U1
0.120
3.0
12
0.3
4S1
0.160
4.0
16
0.4
4SB
0.160
4.0
16
0.4
6U1
0.240
6.0
24
0.6
6C
0.250
6.4
25
0.6
8C
0.500
13
50
1.3
15U1
0.600
15
60
1.5
10C
0.750
20
75
2.0
10CU
1.000
25
100
2.5
30U1
1.200
30
120
3.0
12CU
2.000
50
200
5.0
60U1
2.400
60
240
6.0


MODERATE TEMPERATURE SENSORS:
CRYOGENIC TO +400° F (+200° C), SENSOR DEPENDENT

SENSOR
click to view
STANDARD
MEASURING
RANGE
TARGET
MATERIAL
STATIC
RESOLUTION
 
inch
mm
non-fer
ferrous
μ in
μ m
1UEP
0.040
1.0
4
0.1
2SMT
0.100
2.5
10
0.3
6CMT
0.250
6.4
25
0.6
8CMT
0.500
13
50
1.3
9U
0.160
4.0
16
0.4
12U
0.200
5.0
20
0.5
16U
0.320
8.0
32
0.8
26U
0.500
12
50
1.2
38U
0.750
20
75
2.0
51U
1.000
25
100
2.5

 

DECLARATION OF CONFORMITY

Model Number
KD-2306 non-contact linear proximity/displacement measuring system

Manufacturer
Kaman Precision Products
Measuring & Memory Systems
217 Smith Street
Middletown, CT 06457
USA
Telephone 860-632-1000
Fax 860-632-4515

Conforms with Applicable Standards of:
Council Directive 89/336/EEC as amended by Council Directive 92/31/EEC (EMC Directive)
Council Directive 73/23/EEC as amended by Council Directive 93/68/EEC (LVD Directive)

EMC
EN 61326-1:2006 - Industrial Electrical equipment for Measurement, Control and Laboratory Use – EMC

EN 55011:2007 – Class A Group 1 Radiated Emissions Requirements

LVD
EN 61010-1:2001 The KD-2306 unit requires the use of a limited energy power supply circuit per EN 61010-1:2001 Article 9.3. The KD-2306 does not use or switch voltages in excess of 60 VDC or 42.4 VAC peak (30 VAC rms).

 


Many options are available to customize a standard system to meet the exact needs of the application. The most popular are:

Sensor Cables

Sensor cable extension
Most sensors can handle longer cable lengths, although increasing the cable length can and will affect some performance specifications. Shorter than standard cable lengths are also available. Call an apps engineer to discuss your particular requirements.

In-line cable connector splice
Many sensors come with integral sensor cables. Routing this cable in some applications is difficult and something you only want to do once. Including an in-line connector splice in the cable, near the sensor itself, allows for easy sensor replacement should the need arise.

Hermetic in-line connector splice
Some applications pass the sensor through a pressure boundary, most commonly a vacuum chamber wall. We offer an in-line hermetic bulkhead splice for these applications.

Special Calibrations

Range
Standard published ranges are based on meeting a set of performance specs. Custom calibrations are possible to meet specific application needs. Contact a Kaman applications engineer if a custom calibration is desired.

Target material
Unless otherwise specified, nonferrous systems will be calibrated with an aluminum target, ferrous systems will be calibrated with a 4130 steel target. If your target material is significantly different in conductivity and/or permeability it may be best to calibrate using the same material as your target.

Temperature compensation
When the standard thermal sensitivity of 0.1%FS/°F is not enough, a temperature compensated calibration can be performed that will improve the thermal sensitivity to 0.02%FS/°F. This is accomplished over a customer specified 100°F range with the upper limit of that range <150°F. Larger ranges and higher temperatures are also possible on a best effort basis.

Output
Besides the standard 0-10VDC output, the KD-2306 offers a 4-20mA output and a differential 0-10VDC output.

Synchronization
When multiple channels are used in such a way that the sensors themselves are in close proximity to each other (within 3 sensor diameters), synchronizing the oscillators of the electronics modules will eliminate the resulting beat note interference that will be seen as noise on the outputs.

Log Amp Bypass
When extremely short range calibrations are required/desired, bypassing the log amplifier reduces noise improving performance.

 

Terms of Use  |  Privacy Policy  |  Site Map

Copyright © 2016 Kaman Precision Products  |  Measuring, a division of Kaman Aerospace Corp.