800-552-6267

KD-5100
Differential resolution to a nanometer

> Two precisely matched sensors per channel give resolution to a nanometer.
> Superior thermal and long-term stability of 5x10-6
inches/month or better.
> Small package size: 2 x 2.12 x 0.75 inches thick.
> Cryogenic sensors available.
> High sensitivity: up to 10 V/mil (394 mV/µm).
> Low power consumption: less than 2W @ ±15 Vdc typical.

 

 

KD-5100 photo

  • KD-5100 DATA SHEET PDF
  • KD-5100 MANUAL PDF
  • 3D MODEL
  • SPECS
  • SENSORS
  • OPTIONS
  • ACCESSORIES

KD-5100 Data SheeticonKD-5100 Data Sheet.pdf

 

 

 

 

 

 

 

SMT-9700 Product ManualiconKD-5100 User Manual

 

 

 

 

 

 

 

 

 

 


Electronics
IGS format
STEP format
KD-5100

Sensor
IGS format
STEP format
15N sensor
20N sensor

 


FOR AN ALUMINUM TARGET

Nonlinearity ±0.1% to ±0.5% FSO;
application dependent.
Output ±10 Vdc maximum
Long-term stability (nominal; stabilized at 70°F
[21°C] scale factor dependent)
5 x 10-6 inches/month
(1.27 x 10-4 mm/month)
Thermal sensitivity at null; application dependent;
<5 mV per °F.
Frequency response 22 kHz ±5% @ 3 db
RMS input displacement resolution (if bandwidth limited to 5 kHz):
4x10-9 x √bandwidth in Hz = in.
1x10-7 x √bandwidth in Hz = mm
Input voltage ±15 Vdc @ 55 mA typical
Power consumption <2 watts - system
Power dissipation <0.5 mW per 15N sensor
<1.5 mW per 20N sensor
Output characteristics <5 W @ 5 mA
Operating temperature range
Electronics
Sensors
Cryogenic 20N sensor

-4°F to +140°F (-20°C to +60°C)
62°F to +220°F (-52°C to +105°C)
+4°K to +220°F (+105°C)
Storage temperature range
Electronics
Sensors
Cryogenic 20N sensor

26°F to +180°F (-32°C to +82°C)
-62°F to +220°F (-52°C to +105°C)
+4°K to +220°F (+105°C)
Weight (with 5-foot cable)
Electronics
15N-001 sensor
20N sensor

2.5 ounces (70 grams)
0.61 ounces (17.3 grams)
0.59 ounces (16.8 grams)

 

KD-5100 SPECIFICATIONS
FOR AN ALUMINUM TARGET

       
RESOLUTION
SENSOR
click to view
MAX RANGE
±inch/±mm
TYPICAL NULL
inch/mm
STATIC
inch/mm
1KHz
inch/mm
5KHz
inch/mm
15N
±0.035/±0.89
0.045/1.14
4x10-9/1x10-7
1.3x10-7/3.3x10-6
2.8x10-7/7.2x10-6
20N
±0.075/±1.27
0.090/2.29
4x10-9/1x10-7
1.3x10-7/3.3x10-6
2.8x10-7/7.2x10-6

 

 


Many options are available to customize a standard system to meet the exact needs of the application. The most popular are:

Sensor Cables

Sensor cable extension
Most sensors can handle longer cable lengths, although increasing the cable length can and will affect some performance specifications. Shorter than standard cable lengths are also available. Call an apps engineer to discuss your particular requirements.

In-line cable connector splice
Many sensors come with integral sensor cables. Routing this cable in some applications is difficult and something you only want to do once. Including an in-line connector splice in the cable, near the sensor itself, allows for easy sensor replacement should the need arise.

Hermetic in-line connector splice
Some applications pass the sensor through a pressure boundary, most commonly a vacuum chamber wall. We offer an in-line hermetic bulkhead splice for these applications.

Special Calibrations

Range
Standard published ranges are based on meeting a set of performance specs. Custom calibrations are possible to meet specific application needs. Contact a Kaman applications engineer if a custom calibration is desired.

Target material
Unless otherwise specified, nonferrous systems will be calibrated with an aluminum target. If your target material is significantly different in conductivity and/or permeability it may be best to calibrate using the same material as your target.

 