KDM-8206
Modular rack-mounted multi-channel position sensing system
- Modularized rack format — add channels by installing modular PC backplane boards
- Standard 3U by 7T Eurocard measuring modules
- Resolution to 10 microinches or better (0.01% of full scale)
- Multiple channels; rack-mounted or bench-top enclosures
- Auto-synchronization of multiple channels
- 21 standard-temperature sensors and 10 moderate-temperature sensors
- Non-linearity under 1% of full scale
- Frequency response 50 KHz standard, up to 120 KHz optional
- Outputs: single-ended voltage, differential voltage, or 4-20 mA current
- Measures ferrous and non-ferrous targets
- 12-channel full rack, 9-channel mid-rack, and 6-channel half-rack enclosures; NEMA enclosures available
- RoHS compliant, CE Marked
Specifications
| Resolution | 10 microinches or better (0.01% of full scale) |
|---|---|
| Non-linearity | Under 1% of full scale |
| Frequency response | 50 KHz standard; up to 120 KHz optional |
| Output options | Single-ended voltage, differential voltage, or 4-20 mA current |
| Module format | 3U by 7T Eurocard |
| Standard-temperature sensors | −67°F to +220°F (−55°C to +105°C) — 21 options |
| Moderate-temperature sensors | Cryogenic to +400°F (+200°C), sensor dependent — 10 options |
| Enclosures | 12-channel full rack, 9-channel mid-rack, 6-channel half-rack; NEMA available |
| Rack power | 110/220 VAC, 50/60 Hz |
| Thermal sensitivity | Standard 0.1% FS/°F; compensated 0.02% FS/°F |
Sensors
Downloads
Certifications
DECLARATION OF CONFORMITY
Model Number
KDM-8206 modular rack-mounted multi-channel position sensing system
Conforms with Applicable Standards of:
Council Directive 89/336/EEC as amended by 92/31/EEC (EMC Directive)
Council Directive 73/23/EEC as amended by 93/68/EEC (LVD Directive)
EMC
EN 61326:1998 — Electrical Equipment for Measurement, Control and Laboratory Use
RoHS compliant, CE Marked. To maintain the CE mark, I/O cable length is limited to 30 m (100 ft).
Options
Accessories
Rack and NEMA enclosures, sensors, and cables are available. See the Accessories data sheet for details.
Frequently Asked Questions
How does the KDM-8206 scale to many channels?
Each channel is a 3U-by-7T Eurocard measuring module. You add channels by installing modules into empty rack or bench-top slots — up to 12 in a full rack — with auto-synchronization across channels.
What resolution and bandwidth does it offer?
Resolution to 10 microinches or better (0.01% of full scale), non-linearity under 1% FS, and frequency response of 50 KHz standard (up to 120 KHz optional).
What sensors does it support?
21 standard-temperature sensors (−67°F to +220°F) and 10 moderate-temperature sensors (cryogenic to +400°F), measuring both ferrous and non-ferrous targets. It also drives Kaman’s extreme-environment high-temperature sensors.